Authorization Object: Q_CHAR_PRC
Recording Authorization For Insp. Results In An Operation
Category: Results Recording
Definition
You require this authorization to record or modify results for
inspection characteristics in an operation.
The functions that are permitted for processing the inspection
characteristics can be defined as required by assigning the
authorizations accordingly.
Click on the objects below, to expand data.
Object Fields
The list below includes the object’s fields, ordered by industry-standard importance:
ARBPL | Work Center | Filled in 47% of cases |
QESTATNEW | Final Status Of The Inspection Characteristic (Sample) | Filled in 34% of cases |
QESTATOLD | Initial Status Of Inspection Characteristic (Sample) | Filled in 34% of cases |
WERKS | Plant | Filled in 43% of cases |
Popularity Statistics
Average popularity of Q_CHAR_PRC in roles: 0% (What does this mean?)
Average popularity of Q_CHAR_PRC by users: 1% (What does this mean?)
Object Q_CHAR_PRC is frequently used by users in the following areas:
BC:Basis Components
CO:Controlling
Environmental Analysis
1. Common authorization objects used with Q_CHAR_PRC:
I_AUART | PM: Order Type | Objects appear together in 73% of cases |
C_STUE_BER | CS BOM Authorizations | Objects appear together in 60% of cases |
C_KAPA_ABG | CIM: Capacity Leveling | Objects appear together in 56% of cases |
I_INGRP | PM: Maintenance Planner Group | Objects appear together in 56% of cases |
I_IWERK | PM: Maintenance Planning Plant | Objects appear together in 56% of cases |
I_KOSTL | PM: Cost Centers | Objects appear together in 56% of cases |
I_SWERK | PM: Maintenance Plant | Objects appear together in 56% of cases |
B_USERST_T | Status Management: Set/Delete User Status Using Process | Objects appear together in 52% of cases |
C_AFKO_ATY | CIM: Order Category | Objects appear together in 52% of cases |
C_AFKO_AWA | CIM: Authorization For Prod.Order/Order Type/Plant/Activity | Objects appear together in 52% of cases |
C_AFKO_AWK | CIM: Plant For Order Type Of Order | Objects appear together in 52% of cases |
C_AFRU_APL | Confirmation: Authorization For Actual Work Center | Objects appear together in 52% of cases |
C_FVER_WRK | PP-PI: Production Version – Plant | Objects appear together in 52% of cases |
C_CREC_WRK | PP-PI: Control Recipe – Plant | Objects appear together in 47% of cases |
Q_VORG_MEL | Business Process Quality Notifications | Objects appear together in 47% of cases |
I_QMEL | PM/QM: Notification Types | Objects appear together in 43% of cases |
M_MATE_CHG | Material Master: Batches/Trading Units | Objects appear together in 43% of cases |
Q_UD_CODE | Using Usage Decision Codes | Objects appear together in 43% of cases |
Q_MASTERD | Authorization For Master Data | Objects appear together in 39% of cases |
Q_SPC | Change To Control Charts | Objects appear together in 39% of cases |
B_USERSTAT | Status Management: Set/Delete User Status | Objects appear together in 34% of cases |
C_AFRU_AWK | CIM: Confirmation | Objects appear together in 34% of cases |
C_KLAH_BKP | Authorization For Class Maintenance | Objects appear together in 34% of cases |
I_TCODE | PM: Transaction Code | Objects appear together in 34% of cases |
Q_GP_CODE | Use Of Group Codes | Objects appear together in 26% of cases |
Q_INSPTYPE | Inspection Type For The Insp. Lot | Objects appear together in 26% of cases |
Q_QMEL | Quality Notification Types | Objects appear together in 26% of cases |
Q_TCODE | QM Transaction Authorization | Objects appear together in 26% of cases |
C_TCLS_BER | Authorization For Org. Areas In Classification System | Objects appear together in 21% of cases |
C_TCLS_MNT | Authorization For Characteristics Of Org. Area | Objects appear together in 21% of cases |
C_TCLA_BKA | Authorization For Class Types | Objects appear together in 4% of cases |
Q_INSP_FIN | Inspection Completion With Open Char./Insp.Pts Req. Conf. | Objects appear together in 4% of cases |
Q_MATERIAL | Material Authorization | Objects appear together in 0% of cases |
S_TCODE | Transaction Code Check At Transaction Start | Objects appear together in 0% of cases |
2. Appearance of Q_CHAR_PRC in T-Codes:
QAS3 | Upload Results (Obsolete) | Used in 100% of cases |
QE01 | Record characteristic results | Used in 95% of cases |
QE02 | Change characteristic results | Used in 95% of cases |
QE04 | Record sample results | Used in 95% of cases |
QE05 | Change sample results | Used in 95% of cases |
QE11 | Record results for inspection point | Used in 95% of cases |
QE12 | Change results for inspection point | Used in 95% of cases |
QE14 | Record results for delivery note | Used in 95% of cases |
QE15 | Change results for delivery note | Used in 95% of cases |
QE17 | Record results for equipment | Used in 95% of cases |
QE18 | Change results for equipment | Used in 95% of cases |
QE20 | Record results for funct. location | Used in 95% of cases |
QE21 | Change results for funct. location | Used in 95% of cases |
QE51 | Results recording worklist | Used in 95% of cases |
QE53 | Worklist: Record results for equip. | Used in 95% of cases |
QE54 | Worklist: Results for funct. loctns | Used in 95% of cases |
QE72 | Tabular Results Rec. for Insp. Lots | Used in 95% of cases |
QE73 | Tabular res. recording for characs. | Used in 95% of cases |
QF11 | Record defects for inspection lot | Used in 95% of cases |
QF21 | Record defects for operation | Used in 95% of cases |
QF31 | Record defects for characteristic | Used in 95% of cases |
QE24 | Change results for phys. sample | Used in 91% of cases |
QE52 | Worklist: Results for phys. sample | Used in 91% of cases |
QE71 | Tabular res. recording for insp. pts | Used in 91% of cases |
QEW01 | Results Recording on Web | Used in 91% of cases |
QF01 | Record defect data | Used in 91% of cases |
QF02 | Change defect data | Used in 91% of cases |
COR1 | Create Process Order | Used in 82% of cases |
QEH1 | Worklist for Mobile Results Rec. | Used in 82% of cases |
COR2 | Change Process Order | Used in 78% of cases |
QF03 | Display defect data | Used in 78% of cases |
QE51N | Results Recording Worklist | Used in 73% of cases |
QE23 | Record results for phys. sample | Used in 69% of cases |