Authorization Object: Q_MASTERD
Authorization For Master Data
Category: Basic Data
Definition
This authoriztation controls access to the following QM master data:
Inspection method
Inspection characteristic
Sample-drawing procedure
Click on the objects below, to expand data.
Object Fields
The list below includes the object’s fields, ordered by industry-standard importance:
QMASTAUTH | Authorization Group QM Basic Data | Filled in 20% of cases |
QMASTMOD | Activity For QM Master Data Authorizations | Filled in 100% of cases |
Popularity Statistics
Average popularity of Q_MASTERD in roles: 0% (What does this mean?)
Average popularity of Q_MASTERD by users: 1% (What does this mean?)
Object Q_MASTERD is frequently used by users in the following areas:
BC:Basis Components
Environmental Analysis
1. Common authorization objects used with Q_MASTERD:
I_AUART | PM: Order Type | Objects appear together in 75% of cases |
Q_CERT_PRF | Maintenance Of Certificate Profiles | Objects appear together in 75% of cases |
Q_PLN_FEAT | Maintaining Task List Characs. For A Task List Type | Objects appear together in 75% of cases |
C_AENR_ERW | CC Eng. Chg. Mgmt. Enhanced Authorization Check | Objects appear together in 70% of cases |
Q_STA_QMTB | Maintain Inspection Methods Depending On Status | Objects appear together in 70% of cases |
Q_STA_QPMK | Maintain Master Inspection Characs. Depending On Status | Objects appear together in 70% of cases |
C_AENR_BGR | CC Change Master – Authorization Group | Objects appear together in 60% of cases |
C_CABN | Authorization For Characteristics Maintenance | Objects appear together in 55% of cases |
S_TABU_DIS | Table Maintenance (Via Standard Tools Such As SM30) | Objects appear together in 55% of cases |
C_DRAW_BGR | Authorization For Authorization Groups | Objects appear together in 50% of cases |
C_AFRU_APL | Confirmation: Authorization For Actual Work Center | Objects appear together in 45% of cases |
C_ROUT | Authorizations For Routings | Objects appear together in 45% of cases |
Q_ROUT | Maintain Inspection Plan | Objects appear together in 45% of cases |
C_DRAD_OBJ | Create/Change/Display/Delete Object Link | Objects appear together in 40% of cases |
C_DRAW_DOK | Authorization For Document Access | Objects appear together in 40% of cases |
C_DRAW_TCD | Authorization For Document Activities | Objects appear together in 40% of cases |
C_DRAW_TCS | Status-Dependent Authorizations For Documents | Objects appear together in 40% of cases |
C_KLAH_BKL | Authorization For Classification | Objects appear together in 40% of cases |
I_INGRP | PM: Maintenance Planner Group | Objects appear together in 40% of cases |
I_IWERK | PM: Maintenance Planning Plant | Objects appear together in 40% of cases |
I_KOSTL | PM: Cost Centers | Objects appear together in 40% of cases |
I_QMEL | PM/QM: Notification Types | Objects appear together in 40% of cases |
I_SWERK | PM: Maintenance Plant | Objects appear together in 40% of cases |
M_MATE_CHG | Material Master: Batches/Trading Units | Objects appear together in 40% of cases |
Q_UD_CODE | Using Usage Decision Codes | Objects appear together in 40% of cases |
C_AFRU_AWK | CIM: Confirmation | Objects appear together in 35% of cases |
C_KLAH_BKP | Authorization For Class Maintenance | Objects appear together in 35% of cases |
Q_CHAR_PRC | Recording Authorization For Insp. Results In An Operation | Objects appear together in 30% of cases |
Q_INSP_FIN | Inspection Completion With Open Char./Insp.Pts Req. Conf. | Objects appear together in 30% of cases |
Q_INSPTYPE | Inspection Type For The Insp. Lot | Objects appear together in 30% of cases |
Q_QMEL | Quality Notification Types | Objects appear together in 30% of cases |
Q_SPC | Change To Control Charts | Objects appear together in 30% of cases |
C_TCLS_MNT | Authorization For Characteristics Of Org. Area | Objects appear together in 25% of cases |
I_TCODE | PM: Transaction Code | Objects appear together in 25% of cases |
Q_MATERIAL | Material Authorization | Objects appear together in 25% of cases |
C_TCLS_BER | Authorization For Org. Areas In Classification System | Objects appear together in 15% of cases |
Q_GP_CODE | Use Of Group Codes | Objects appear together in 15% of cases |
C_TCLA_BKA | Authorization For Class Types | Objects appear together in 5% of cases |
Q_TCODE | QM Transaction Authorization | Objects appear together in 0% of cases |
2. Appearance of Q_MASTERD in T-Codes:
CWBQM | QM: Engineering Workbench | Used in 95% of cases |
QC01 | Create certificate profile | Used in 95% of cases |
QC02 | Change certificate profile | Used in 95% of cases |
QE01 | Record characteristic results | Used in 95% of cases |
QE04 | Record sample results | Used in 95% of cases |
QE11 | Record results for inspection point | Used in 95% of cases |
QE14 | Record results for delivery note | Used in 95% of cases |
QE17 | Record results for equipment | Used in 95% of cases |
QE20 | Record results for funct. location | Used in 95% of cases |
QP01 | Create | Used in 95% of cases |
QP02 | Change | Used in 95% of cases |
QPV2 | Maintain sample drawing procedure | Used in 95% of cases |
QS61 | Maintain material specification | Used in 95% of cases |
QS63 | Maintain material spec: Planning | Used in 95% of cases |
QS21 | Create master insp. characteristic | Used in 90% of cases |
QS22 | Create master insp. charac. version | Used in 90% of cases |
QS23 | Change master insp. charac. version | Used in 90% of cases |
QS25 | Delete master insp. charac. version | Used in 90% of cases |
QS27 | Replace master insp. characteristic | Used in 90% of cases |
QS31 | Create inspection method | Used in 90% of cases |
QS32 | Create inspection method version | Used in 90% of cases |
QS33 | Change inspection method version | Used in 90% of cases |
QS35 | Delete inspection method version | Used in 90% of cases |
QS37 | Central replacement of methods | Used in 90% of cases |
QS34 | Display inspection method version | Used in 80% of cases |
QE51N | Results Recording Worklist | Used in 70% of cases |
QS24 | Display master insp. charac. version | Used in 70% of cases |
QE23 | Record results for phys. sample | Used in 65% of cases |